Home > Products > Refrigeration Solenoid Valve > Danfoss Type Solenoid Valve > EVR25 Refrigeration Solenoid Valve

EVR25 Refrigeration Solenoid Valve

Payment Type:
L/C,T/T,Paypal,Western Union
Incoterm:
FOB,CFR,CIF,EXW
Min. Order:
1 Set/Sets
Transportation:
Ocean,Land,Air
Port:
Dalian,Tianjin,Shanghai
Share:
Chat Now
  • Product Description
Overview
Product Attributes

Model No.EVR25

BrandBrando

ActuatorElectric

Connection FormFlange

TypeDirect Acting

MaterialCast Iron

PressureOrdinary Temperature

Valve StructureDirect-Acting Piston Structure

Power SupplyDC Solenoid Valve

UsageFlow Control

StandardGB

ApplicationRefrigeration Units

Supply Ability & Additional Information

PackagingBox Carton Pallet

Productivity2460 sets per month

TransportationOcean,Land,Air

Place of OriginNINGBO

Supply Ability650 sets per week

CertificateCE

PortDalian,Tianjin,Shanghai

Payment TypeL/C,T/T,Paypal,Western Union

IncotermFOB,CFR,CIF,EXW

Packaging & Delivery
Selling Units:
Set/Sets
Package Type:
Box Carton Pallet

EVR25 Refrigeration Solenoid Valve


Direct opening and closing type EVR refrigeration Solenoid Valve is simple in structure, but it relies on electromagnetic force to open and close. When the pressure difference between inlet and outlet is large, the solenoid valve is difficult to open and cannot run quickly. Therefore, this solenoid valve is only suitable for small freon refrigeration system.



Technical data:

Models
Connection size
H1
H2
H4
L
L2

KV 

(m³/h)

SAE inlet/outlet ODF inlet/outlet  Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm
EVR3-014 EVR3-014S 1/4 6 0.5 14 2.8 71 - - 4.0 102 0.3 7 0.27
EVR3-038 EVR3-038S 3/8 10 0.5 14 2.9 73 - - 4.6 117 0.4 10
EVR6-038 EVR6-038S 3/8 10 0.5 14 3.1 79 - - 4.4 111 0.4 10 0.8
EVR6-012 EVR6-012S 1/2 12.8 0.5 14 3.1 79 - - 5.0 127 0.4 10
EVR10-012 EVR10-012S 1/2 12.8 0.6 16 3.1 79 - - 5.0 127 0.4 10 1.9
EVR10-058 EVR10-058S 5/8 16 0.6 16 3.1 79 - - 6.3 160 0.5 12

EVR15-058S 5/8 16 0.7 19 3.4 86 - - 6.9 176 0.5 12 2.6

EVR15-078S 7/8 22 0.7 19 3.4 86 - - 6.9 176 0.7 17

EVR20-078S 7/8 22 0.8 20 3.5 90 - - 7.5 191 0.7 17 5

EVR20-118S 1 1/8 28.8 0.8 20 3.5 90 - - 8.4 214 0.8 22

EVR22-138S 1 3/8 35 0.8 20 3.5 90 - - 11.1 281 1 25 6

EVR25-118S 1 1/8 28.8 1.5 38 5.4 138 2.8 72 10.0 256 0.8 22 10

EVR25-138S 1 3/8 35 1.5 38 5.4 138 2.8 72 11.0 281 1 25

EVR32-138S 1 3/8 35 1.9 47 4.4 111 2.1 53 11.0 281 1 25 16

EVR32-158S 1 5/8 42 1.9 47 4.4 111 2.1 53 11.0 281 1.1 29

EVR40-158S 1 5/8 42 1.9 47 4.4 111 2.1 53 11.0 281 1.1 29 25

EVR40-218S 2 1/8 54 1.9 47 4.4 111 2.1 53 11.0 281 1.3 34

Main dimension of EVR25 Refrigeration Solenoid Valve:

Main dimension of EVR25 Refrigeration Solenoid Valve:


Refrigeration parts (EVR25 Refrigeration Solenoid Valve):

Refrigeration parts (EVR25 Refrigeration Solenoid Valve)


EVR25 Refrigeration Solenoid Valve applies to refrigeration machines:

EVR25 Refrigeration Solenoid Valve applies to refrigeration machines

Fault phenomenon solution of EVR25 Refrigeration Solenoid Valve:


Fault phenomenon 1: EVR solenoid valve does not change direction
If the solenoid valve core or the slide block cannot move, but is fixed in a position, then the air conditioner refrigeration or the heating cannot exchange. Generally the most common fault can only be refrigeration, not heating, at the same time cause the air conditioner protection against cold air, outdoor machine operation, indoor machine does not blow hot air, after the failure light display stop.

Fault phenomenon 2: EVR Solenoid Valve Coil short circuit
When the air conditioner is running, the solenoid valve coil is too large because of short circuit and the current is too large.

Failure phenomenon 3: EVR electromagnetic valve slider deformation
If the slide block is deformed, even if the solenoid valve coil has been energized, the guide valve valve core will not move, resulting in the slide block reversing is not in place, so that the valve body internal air, compressor high pressure gas form a short cycle, causing high temperature, high pressure, until frequent thermal protection, and finally burned the insulation layer of the compressor. For the system as a whole, the high pressure of the globe valve leaks to the low pressure end, reducing the high/low pressure differential. Often not refrigeration, not heating or poor results.

Welcome to your inquiry!

Product Categories : Refrigeration Solenoid Valve > Danfoss Type Solenoid Valve

Home > Products > Refrigeration Solenoid Valve > Danfoss Type Solenoid Valve > EVR25 Refrigeration Solenoid Valve
Email to this supplier
  • *Subject:
  • *To:
    Mr. Brandon Bao
  • *Mobile:
  • *Email:
  • *Message:
    Your message must be between 20-8000 characters
Send Inquiry
*
*
*

Related Products List

Home

Product

Whatsapp

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send