Home > Products > Pneumatic Valve > Pneumatic Solenoid Valve > 5/2 Way Pneumatic Valve 4V310-08

5/2 Way Pneumatic Valve 4V310-08

$6 - 7 /Piece/Pieces
Payment Type:
T/T,Paypal,Western Union
Incoterm:
FOB,CFR,CIF,EXW,FCA,CPT,CIP
Min. Order:
200 Piece/Pieces
Transportation:
Ocean,Land,Air
Port:
Ningbo,Shanghai,Tianjing
Share:
Chat Now
  • Product Description
Overview
Product Attributes

Model No.4V310-08

BrandOEM

BrandOther

CustomizedCustomized

CertificationCE

PowerPneumatic

PressureMedium Pressure

Work TemperatureNormal Temperature

MaterialAluminum

Supply Ability & Additional Information

Packagingboxes,cartons,pallets

Productivity100000pcs per month

TransportationOcean,Land,Air

Place of OriginNingbo,China

Supply Ability100000pcs per month

CertificateCE.ISO

PortNingbo,Shanghai,Tianjing

Payment TypeT/T,Paypal,Western Union

IncotermFOB,CFR,CIF,EXW,FCA,CPT,CIP

Packaging & Delivery
Selling Units:
Piece/Pieces
Package Type:
boxes,cartons,pallets

5/2 Way Pneumatic Valve 4V310-08


300Sries Solenoid Pneumatic Valve High precision guide ring, high frequency more stable, longer life; High frequency leader, not easy to be stuck, responsive; Secret modulation grease, lasting moistens, reduces the friction; Full turns good coil, not easy to hot, more durable.

Model

4V310-08/10

Working voltage

12V DC

Position and way NO.

5/2 way

Effective area

25mm2(CV=1.40)

Port size

1/4" ,3/8"

Fluid

40 micron filtered air

Operation

Inside pilot type

Operating pressure

0.15~0.8MPa

Max.proof pressure

1.2MPa

Temperature

5~50 C

Lubrication

No required

Power consumption

AC:2.5VA DC:2.5W

Coil insulation &protection grade

Class F.IP65

Electriacl entry

Connector

Higest action frequency

5 cycle/second

Working Voltage

DC12V DC24V AC110V AC220V AC24V AC380V

tz



11



10


The following points for installation of Solenoid Valve are as follows:
1, installation should pay attention to the arrow on the valve body should be consistent with the media flow direction. Do not install in places where there is direct drip or splash. Solenoid valves should be installed vertically.
2, solenoid valves should be guaranteed to operate normally within the 15%-10% range of the rated voltage.
3. After installing the solenoid valve, there should be no reverse pressure difference in the pipeline. It needs to be energized several times to make it warm enough to be put into operation.
4. Solenoid valve should be thoroughly cleaned before installation. The medium should be free of impurities. Filter before valve.
5, when the solenoid valve malfunctions or cleaning, to ensure that the system continues to operate, it should install bypass devices.



Fault and elimination
First, the solenoid valve does not work after energizing.
Check whether power wiring is bad, re wiring and connector connection.
Check whether the supply voltage is within the range of + - to normal location.
Whether the coil is removed or re welded
Coil short circuit to replace coil
Is the working pressure difference inappropriate? Adjust the differential pressure to replace the equivalent solenoid valve.
The fluid temperature is too high to replace the proportionate solenoid valve.
Impurities jam the main valve core and the moving iron core of the solenoid valve for cleaning, if the seal is damaged, replace the seal and install the filter
The viscosity of the liquid is too high, the frequency is too high, and the life has arrived.
Two, solenoid valve can not be closed.
Seal of main spool or iron core has been damaged. Replace seal.
If the fluid temperature and viscosity are too high, replace the counterpart solenoid valves.
The impurity enters the electromagnetic valve to produce the valve core or the moving iron core.
The life of springs has arrived or deformed to replace.
Throttle hole balance hole clogging and timely cleaning
Working frequency is too high or life expectancy has changed.
Three, other circumstances
Internal leakage to check whether the seal is damaged, and whether the spring is assembled badly.
Leakage: connect loosening or seal is broken. Tighten screws or replace seals.
There is noise when power is switched on, and the fastener on the head is loose and tightened. Voltage fluctuation is not within the allowable range, adjust the voltage. Clean or replace the impurities or uneven surfaces of the core.




Product Categories : Pneumatic Valve > Pneumatic Solenoid Valve

Home > Products > Pneumatic Valve > Pneumatic Solenoid Valve > 5/2 Way Pneumatic Valve 4V310-08
Email to this supplier
  • *Subject:
  • *To:
    Mr. Brandon Bao
  • *Mobile:
  • *Email:
  • *Message:
    Your message must be between 20-8000 characters
Send Inquiry
*
*
*

Related Products List

Home

Product

Whatsapp

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send