1 Inch Straight Through Pulse Valve 8353G006
The angle between the inlet and outlet of the straight-through electromagnetic pulse valve is 180°The coil in the Solenoid Valve body is input pulse signal through the wire, and the pulse valve is controlled by the output signal of the pulse injection controller. By the pressure change of the two air Chambers before and after the valve, the flexible deformation of the rubber diaphragm realizes the opening and closing of the pulse valve. The diameter of the rubber diaphragm determines the travel size of the rubber diaphragm and the speed of opening and closing.
Construction | |
Body | Aluminum |
Core Spring | Stainless steel |
Sealing &disc | NBR(nitrile/buna-n) |
Diaphragm | TPE(hytrel) |
Shading coil | Copper |
Voltage | DC: 24V, AC:24V,48V,110V,230V,Customized |
Working Temperature | -5 to 55°C |
Protection Class | IP65 |
Coil Insulation Class | F |
Working Pressure | 0.2-0.6Mpa |
Technical parameters and indicators
Working pressure: 0.2mpa ~ 0.6mpa
Air source medium: clean air separated and filtered by oil and water
Protection level: IP65
Voltage: DC24 (AC220V/50Hz)
Current: 0.8a (0.05a)
Service environment:
: under normal temperature 25 ℃ ~ 85 ℃; High temperature: 25 ℃ ~ 230 ℃
The relative humidity of the air does not exceed 85%
Straight through electromagnetic Pulse Valve Diaphragm life: 1 million times
1. AC220V and DC24V are preferred as far as possible for voltage specifications.
2, in the environment with high relative humidity and rain drops and other occasions, should choose Waterproof Solenoid Valve.
3. The rated current and consumed power shall be selected according to the power supply capacity. It shall be noted that the VA value is higher during ac starting, and indirect guided solenoid valve shall be preferred when the capacity is insufficient.
Product Categories : Dust Collector Pulse Valve > Pulse Jet Valve