Model No.: CA89MM
Brand: BRANDO
Number Of Diaphragm: 2
Name: CA102MM Goyen Type Pulse Jet Valve
Remote Or Integral: Integral Piloted
Series: Manifold Mount (MM)
Pipe Size: 3 1/2 Inch
Diaphragm Material: Nitrile
Body Material: ADC Aluminum
Operating Pressure: 3~8bar
Operating Temperature: -5~+55℃
Available Voltages: 24VAC, 110V/120VAC 200/240VAC, 12VDC, 24VDC
Packaging: Box Carton Pallet
Productivity: 10000 sets per week
Transportation: Ocean,Land,Air
Place of Origin: NINGBO CHINA
Supply Ability: 50000 sets per month
Certificate: CE,ISO,GB
Port: Ningbo,Shanghai,Guangzhou
Payment Type: L/C,T/T,Paypal,Money Gram,Western Union
Incoterm: FOB,CFR,CIF,EXW
CA89MM Angle Type Electromagnetic Pulse Valve
What is a Dust Collector Pulse Jet Valve?
Diaphragm pulse valves are the most important components of a baghouse pulse jet cleaning system.
On a pulse jet baghouse pulse valves (also called diaphragm valves) control the release of air pulses during the cleaning cycle. When the baghouse control board or timer board initiates a cleaning cycle it sends an electrical signal to the solenoids, when then activate the pulse valve. Inside the pulse valve, a rubber diaphragm opens and closes to release the compressed air stored in the air header tank. The air then passes through the valve into the blow pipes above the filters and then is directed down into the filters to clean them.
Technical data of MM Series Full Immersion Manifold Flat Mount Valves:
Overall dimension of CA102MM Goyen Replacement Dust Collector Valve:
Details display of CA102MM Goyen Type Dust Collector Pulse Valve:
Spare Parts of Full Immerse Manifold Mounted Pulse Jet Valve:
Part Name Material Solenoid coil Enamelled wire Armature assembly SS304, 430FR Small common cap ADC aluminum (die cast) Diaphragm NBR (Nitrile, buna-n) Top end cap ADC aluminum (die cast) Big spring SS304 Screws SS302 Seal NBR, VITON Main body ADC aluminum (die cast)
Pulse jet valves must do the following safety inspection before it is officially delivered:
1. Insulation resistance test:
(1) Measure the insulation resistance of the solenoid coil to the outer casing under the specified environmental conditions using a 500V meter with a range of 0MΩ to 500MΩ and an accuracy of 1 meter.
(2) Put the valve in the temperature regulation and humidity control box, and set the temperature to 35 degrees, and the relative humidity is 85%, apply a 50Hz, 250V sinusoidal AC voltage between the electromagnetic coil and the valve body for 1min. Check for breakdown.
2. Anti-vibration test: the valve is fixed on the vibration test bench, after the vibration frequency is 20Hz, the full amplitude is 2mm, after 30min vibration, check whether the fasteners of each part of the valve are loose, whether the work is normal.
3. Diaphragm service life test: Connect the clean air of nominal pressure to the air inlet of the electromagnetic pulse valve, and input the nominal voltage value of 0.1s width and interval of 3s on the Solenoid Valve, and record the number of continuous or cumulative work of the valve.
Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing
Welcome to your any question and inquiry!