Model No.: CA45DD
Brand: Brando
Port Size: 1 1/2''
Number Of Diaphragm: 2
Pilot Type: Integral Pilot
Diaphragm Material: Nitrile (Buna)
Supply Voltages: DC24V, AC24V, AC110V, AC220V
Name: CA45DD Goyen Replacement Pulse Jet Valve
Series: DD
Connection Type: Dresser Nut
Operating Pressure Range: 0.3 To 0.8 MPa
Operating Temperature Range: -5 To +55 ℃
Packaging: Pallet, Carton, Box
Productivity: 20000 sets per week
Transportation: Ocean,Land,Air
Place of Origin: Ningbo China
Supply Ability: 100000 sets per month
Certificate: CE,GB,ISO
Port: Ningbo,Shanghai,Guangzhou
Payment Type: L/C,T/T,Paypal,Money Gram,Western Union
Incoterm: FOB,CFR,CIF,EXW
1 1/2'' CA45DD Goyen Replacement Diaphragm Valve AC220V
CA45DD dresser nut pulse jet valve is the heart of pulse jet dust collector. It plays an important role in the pulse jet dust collector. When the CA45DD Pulse Jet Valve is blocked, the resistance of the dust collector will increase and the value of the differential pressure gauge will increase. This will easily cause the dust bag to wear and fall off, which will affect the normal operation of the dust collector.
Overall dimension of CA45DD Goyen Replacement Diaphragm Valve:
Details show of CA45DD Double Dresser Nut Dust Collector Valve:
Technical data of Goyen Type DD Series Dust Collector Valves:
Model No | CA20DD | CA25DD | CA45DD | |
Nominal Size | 20 | 25 | 45 | |
Port Size | mm | 20 | 25 | 40 |
in | 3/4 | 1 | 1 1/2 | |
No of Diaphragms | 1 | 1 | 2 | |
Flow | Kv | 12 | 20 | 44 |
Cv | 14 | 23 | 51 | |
Pressure (Psi) | 5 to 125 | 5 to 125 | 5 to 125 | |
Temperature℃ | NBR | -40 to 82 | -40 to 82 | -40 to 82 |
VITON | -29 to 232 | -29 to 232 | -29 to 232 |
Installation instructions of Dresser Nut Pulse Jet Valves:
The correct use of CA45DD pulse jet valve:
1. The pulse jet valve is a diaphragm valve that is combined with a Solenoid Valve, a pilot valve and a pulse valve, and is directly controlled by an electric signal.
2. The pulse jet valve should not be too loose or too tight, too loose and easy to dust, too tight and easy to pull.
3. The pulse jet valve is preferably installed perpendicular to the horizontal pipe and the coil is upward. Allow ±30° tilt when conditions do not allow. Otherwise, normal use is not guaranteed.
4. The arrow on the valve body of the pulse jet valve should be consistent with the flow direction of the medium.
Focus on your demands, Offer you best solution: √ Contact us if some points you have doubt √ Contact us if somewhere need to change √ Contact us if you are doing designing Welcome to your any question and inquiry!
√ Contact us if not the one you are looking for
Product Categories : Dust Collector Pulse Valve > Pulse Jet Valve
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.