Overview
Product Attributes

Model No.G25

BrandOEM

CustomizedCustomized

PrincipleVacuum Filtration

StructureVertical Type

UsageAir Filter

ApplicationOther

Work TemperatureNormal Temperature

MaterialOem

Supply Ability & Additional Information

Packagingpp bag inside, carton box outside

Productivity100000pcs per month

TransportationOcean,Land,Air

Place of OriginNingbo,China

Supply Ability100000pcs per month

CertificateCE.ISO

PortNingbo,Shanghai,Tianjing

Payment TypeL/C,T/T,Paypal,Western Union

IncotermFOB,CFR,CIF,EXW,FCA,CPT,CIP

Packaging & Delivery
Selling Units:
Piece/Pieces
Package Type:
pp bag inside, carton box outside

1'' Pulse Valve Diaphragm G25 for ASCO type SCG353A044


Our company can be customized according to customer needs of various sizes of diaphragm, diaphragm material use of imported rubber, long service life, good wear resistance A circular membrane-like elastic sensing element. When the two sides of the membrane are subjected to different pressures (or forces), the membrane moves towards the side with lower pressure, causing the displacement of its center in a certain relation to the pressure difference. The types of diaphragm are mainly plain diaphragm, vertical chain diaphragm and corrugated diaphragm.

The flat diaphragm can be divided into various forms according to whether the peripheral support is fixed, whether the center is open or not, and the stress distribution in the diaphragm area, etc. The most commonly used is the flat diaphragm composed of the circular thin plate with the same section with fixed peripheral.

In order to ensure the quality and performance of the products, our company is very strict in selecting the materials and materials. According to the requirements of different customers, we can provide various types of diaphragm products with different materials and structures. The production equipment is perfect and the molds are complete. Professional technology and dedicated spirit is our customers to provide a solid guarantee of products.


Model Number

SCG353A044 Pulse Valve Diaphragm

Working-pressure

0.2--0.6MPa

Ambient Temperature

-20 ~ 80℃

Working Medium

Water/Clean Air

Voltage

AC220V DC24V

Diaphragm Life

Over One Million cycles or 2 years

Center Distance

φ78

Connection Port

G1"

There are various types of Diaphragm can be available

9 10 11

ASCO Pulse Valve Diaphragm failure
1. The spring is damaged. The spring on the pulse valve core is easily damaged.
2, rubber mat damage, after a long time of use, the rubber pad on the pulse valve spool is easy to damage, the appearance is that the pulse valve for a long time to blow air into the nozzle, the treatment is to replace the rubber pad.
3, valve core dirt, because the air intake is not clean, cause the dirt accumulation at the valve core, the appearance is the nozzle long air intake or power pulse valve does not work, the treatment is to clean the valve core.
4. The diaphragm is damaged. After long-term operation, the diaphragm is prone to fatigue and oxidation.
5, orifice, blockage or damage to the intake is not clean easy to cause the clogging in orifice, the appearance is pulse valve to blowing vent mouth for a long time, handling is cleaning the orifice, orifice damaged or missing, the orifice lose intercept, result in normal pressure and the appearance is some action after electric pulse valve, pressure relief vent mouth, but not for injection pulse valve, handling is a change of orifice. The diaphragm is the main component of the pulse valve in the ash cleaning and spraying system of the pulse bag filter. The service life of the diaphragm is usually 1 million times or 3 years.

ASCO Pulse Valve diaphragm repair
The main problem with the ASCO pulse valve is the wear of the ring caused by the compression and loosening of the rubber surface and the front air chamber of the injection, that is, the elastic rubber on the diaphragm surface is worn away. Repair is to restore worn out ring rubber. After cleaning the wear area of the diaphragm, apply TS919 high performance rubber repair agent bonded to the conveyor belt to the wear area of the diaphragm

For more information,please feel free to contact us.


Product Categories : Valve Diaphragm > Other Pulse Valve Diaphragm

Home > Products > Valve Diaphragm > Other Pulse Valve Diaphragm > C113443 C113444 K0200262 K238866 Pulse Valve Diaphragm
Email to this supplier
  • *Subject:
  • *To:
    Mr. Brandon Bao
  • *Mobile:
  • *Email:
  • *Message:
    Your message must be between 20-8000 characters
Send Inquiry
*
*
*

Related Products List

Home

Product

Whatsapp

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send