Home > Products > Valve Diaphragm > Other Pulse Valve Diaphragm > 1.5'' Joil Type Pulse Jet Valve Replacement Diaphragm

1.5'' Joil Type Pulse Jet Valve Replacement Diaphragm

Payment Type:
L/C,T/T,Paypal,Western Union
Incoterm:
FOB,CFR,CIF,EXW,FCA,CPT,CIP
Min. Order:
1 Set/Sets
Transportation:
Ocean,Land,Air
Port:
Ningbo,Shanghai,Tianjing
Share:
Chat Now
  • Product Description
Overview
Product Attributes

Model No.J40

BrandOEM

Supply Ability & Additional Information

PackagingPVC bag, inner box, carton, than packed by pallet; also can be packed by color card and can be customized

Productivity100000pcs per month

TransportationOcean,Land,Air

Place of OriginNingbo,China

Supply Ability100000pcs per month

CertificateCE.ISO

PortNingbo,Shanghai,Tianjing

Payment TypeL/C,T/T,Paypal,Western Union

IncotermFOB,CFR,CIF,EXW,FCA,CPT,CIP

Packaging & Delivery
Selling Units:
Set/Sets
Package Type:
PVC bag, inner box, carton, than packed by pallet; also can be packed by color card and can be customized

1.5'' Joil Type Pulse Jet Valve Replacement Diaphragm


Solenoid coil has one touch terminal blockwith easy electrical wiring.For outdoor use,  use aluminum dicastingmaterial body. A timer controller for quick opening andclosing of valve and a waterproofed,up to 180'C heat resistance coil are used. Diaphragm is manufactured with specialnylon and synthetic rubber,so it is excellent even in any temperature and environment.


Due to Pulse Valve Diaphragm needs from time to time opening and closing action is a flexible mechanism to control the air circulation, has good flexibility and requirements, also demanded the sealing as high as possible, so the pulse Valve Diaphragm material is directly related to the service life of pulse valve diaphragm and using effect, in other words, the pulse valve diaphragm is good or bad will directly affect the working stability of pulse bag filter soot cleaning system, is directly related to the use of dust removal equipment cost, the service life of the general pulse valve diaphragm has or the number of times


Joil Diaphragm repair kits
Type Quantity Suitable valve Material
1" 1 JICI25, JICR25, JISI25, JISR25 Nitril or Viton
1 1/2" 1 JICI40, JICR40, JISI40, JISR40
1 1/2" 2 JICI40, JICR40, JISI40, JISR40
2" 2 JISI50, JISR50
2 1/2" 2 JISI65, JISR65
3" 2 JISI80, JISR80, JIHI80, JIHR80

Various data of Joil Diaphragm J40

11


Installation in Pulse Valve,application in Industrial Dust Collector System

2.1 1.1

 

Installation of Joil type Pulse Valve Diaphragm

1. To avoid any potential operational problems it is preferable that the valves are not mounted underneath the tank where condensation may collect. All o-rings should be

coated with a silicone based lubricant or similar.

2. Dresser nut seals where used are a pressure seal only, not a structural component. Do not rely on dresser seals to retain either the tanks or blowtubes. Tanks and

blowtubes must be independently restrained.

3. Connect to Goyen pilot valve, if remotely actuated.

4. Ensure compressed air supply is dry and free from oil and dirt.

5. Check all cleaning system components are secure before applying pressure.

6. Apply moderate pressure and check for leaks.

7.Fully pressurise system.

8.Test fire and listen for proper actuation and crisp pulse noises.


The role of the electromagnetic valve diaphragm in the dust collector:

To control the size of oil pressure in the oil circuit. Generally, it is installed in the main oil circuit or the shock absorber back pressure oil circuit to reduce the oil pressure impact when changing gears and locking and unlocking, so as to keep the equipment running in a stable state. Our pulsed Solenoid Valve Diaphragm is selected to produce the best quality rubber plate suitable for the production of pulsed valve diaphragm, with strong oil resistance, acid resistance, high temperature resistance, alkali resistance and other characteristics, which can easily ensure the complete synchronous operation with other control components to control the pulse compressed air injection.


Even in extremely harsh working environment, it can guarantee its normal work and long service life. Choose low resistance Solenoid Valve diaphragm: the internal structure of the solenoid valve diaphragm needs to ensure large amount of air injection, the diaphragm stroke is long, the structure of the shell according to the hydrodynamic design of the valve resistance is small.

The selection of pulse valve with low resistance and high injection volume can remove larger area of filter material and greatly save the overall cost of the injection system


If you want to know more,pls feel free to contact us

Product Categories : Valve Diaphragm > Other Pulse Valve Diaphragm

Home > Products > Valve Diaphragm > Other Pulse Valve Diaphragm > 1.5'' Joil Type Pulse Jet Valve Replacement Diaphragm
Email to this supplier
  • *Subject:
  • *To:
    Mr. Brandon Bao
  • *Mobile:
  • *Email:
  • *Message:
    Your message must be between 20-8000 characters
Send Inquiry
*
*
*

Related Products List

Home

Product

Whatsapp

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send