Home > Products > Refrigeration Solenoid Valve > G 5/8'' EVR15 Refrigeration Solenoid Valve
G 5/8'' EVR15 Refrigeration Solenoid Valve
G 5/8'' EVR15 Refrigeration Solenoid Valve
G 5/8'' EVR15 Refrigeration Solenoid Valve
  • G 5/8'' EVR15 Refrigeration Solenoid Valve
  • G 5/8'' EVR15 Refrigeration Solenoid Valve
  • G 5/8'' EVR15 Refrigeration Solenoid Valve

G 5/8'' EVR15 Refrigeration Solenoid Valve

    Payment Type: L/C,T/T,Paypal,Money Gram,Western Union
    Incoterm: FOB,CFR,EXW
    Min. Order: 1 Piece/Pieces
    Delivery Time: 4 Days

Basic Info

Model No.: EVR15-058S

Actuator: Electric

Type: Direct Acting

Material: Cast Iron

Pressure: Ordinary Pressure

Valve Structure: Direct-Acting Piston Structure

Power Supply: AC Solenoid Valve

Usage: Temperature Control

Standard: GB

Application: Industrial Usage

Additional Info

Packaging: Pallet,Carton,Inner Box

Productivity: 4530 sets/ 1 month

Brand: Brando

Transportation: Ocean,Land,Air

Place of Origin: NINGBO CHINA

Supply Ability: 7 hundred sets per week

Certificate: CE

Port: Qindao,Shandong,Tianjin

Product Description

G 5/8'' EVR15 Refrigeration Solenoid Valve


The screw chiller is mainly composed of a screw compressor, a condenser, an evaporator, an expansion valve and an electric control system. The component in which the refrigerant is controlled is a EVR refrigeration Solenoid Valve.



Technical Parameters EVR refrigeration solenoid valve :

Model
Connection
H1
H2
H4
L
L2
KV Factor (m³/h)
SAE inlet/outlet ODF inlet/outlet (Solder) Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm
EVR3-014 EVR3-014S 1/4 6 0.5 14 2.8 71 - - 4.0 102 0.3 7 0.27
EVR3-038 EVR3-038S 3/8 10 0.5 14 2.9 73 - - 4.6 117 0.4 10
EVR6-038 EVR6-038S 3/8 10 0.5 14 3.1 79 - - 4.4 111 0.4 10 0.8
EVR6-012 EVR6-012S 1/2 12.8 0.5 14 3.1 79 - - 5.0 127 0.4 10
EVR10-012 EVR10-012S 1/2 12.8 0.6 16 3.1 79 - - 5.0 127 0.4 10 1.9
EVR10-058 EVR10-058S 5/8 16 0.6 16 3.1 79 - - 6.3 160 0.5 12

EVR15-058S 5/8 16 0.7 19 3.4 86 - - 6.9 176 0.5 12 2.6

EVR15-078S 7/8 22 0.7 19 3.4 86 - - 6.9 176 0.7 17

EVR20-078S 7/8 22 0.8 20 3.5 90 - - 7.5 191 0.7 17 5

EVR20-118S 1 1/8 28.8 0.8 20 3.5 90 - - 8.4 214 0.8 22

EVR22-138S 1 3/8 35 0.8 20 3.5 90 - - 11.1 281 1 25 6

EVR25-118S 1 1/8 28.8 1.5 38 5.4 138 2.8 72 10.0 256 0.8 22 10

EVR25-138S 1 3/8 35 1.5 38 5.4 138 2.8 72 11.0 281 1 25

EVR32-138S 1 3/8 35 1.9 47 4.4 111 2.1 53 11.0 281 1 25 16

EVR32-158S 1 5/8 42 1.9 47 4.4 111 2.1 53 11.0 281 1.1 29

EVR40-158S 1 5/8 42 1.9 47 4.4 111 2.1 53 11.0 281 1.1 29 25

EVR40-218S 2 1/8 54 1.9 47 4.4 111 2.1 53 11.0 281 1.3 34


Other technical data of EVR refrigeration solenoid valve:

Applicable Refrigerant HCFC or HFC or CFC or customized
Applicable Medium Temperature -40~105℃
Applicable Ambient -40~80℃
Standard Voltage of Solenoid Coil AC380V AC220V 50/60HZ
Allowable Voltage Fluctuation for Solenoid +10%~-15%
Connection of Solenoid Terminal box


Component schematic of EVR15-058S refrigeration solenoid valve:

Component schematic of EVR15-058S refrigeration solenoid valve


Packing Carton picture of EVR15-058S air conditioning solenoid valve:

Packing Carton picture of EVR15-058S air conditioning solenoid valve

Payment and delivery of EVR15-058S refrigerator solenoid valves:



The compressor runs too long
The root cause of the compressor running time is too long, the cooling capacity of the device is insufficient or the heat load of the cold storage is too large. The main ones are:

1. The evaporator is too thick or too oily;

2. The circulation of refrigerant in the system is insufficient, or the liquid refrigerant pipeline is not smooth enough;

3. The actual gas delivery volume of the compressor is significantly reduced due to leakage of the suction and exhaust valve, serious leakage of the piston ring or failure of the compressor to load.

4. The thermal load of the cold storage is too large due to the insulation damage of the cold storage, the tightness of the warehouse door or the release of a large number of hot goods;

5, the temperature relay, low-voltage relay or liquid supply solenoid valve and other control components fail, so that the library temperature has reached the lower limit. But the compressor can't stop in time.

High and low pressure rapid balance after compressor shutdown
This is mainly due to the serious leakage or breakage of the suction and exhaust valve, as well as the gasket breakdown between the cylinder high and low pressure, and the high pressure gas quickly enters the suction chamber after the shutdown.

The compressor cannot be loaded or unloaded normally
For the oil pressure control energy regulation system, the main reasons are: the oil pressure is too low. (Generally caused by excessive bearing clearance and excessive pump clearance), it can be solved by tightening the oil pressure regulating valve; the piston of the unloading cylinder is seriously leaking oil, the oil circuit is blocked; the cylinder is stuck with the piston or other mechanism; the solenoid valve does not move. Spirit, or iron core has remanence.


Welcome to your inquiry!


Looking for ideal CFC/HCFC/HFC Refrigerant Manufacturer & supplier ? We have a wide selection at great prices to help you get creative. All the Refrigeration/freezing/air Conditioning Plant are quality guaranteed. We are China Origin Factory of Suitable for All Fluoride Refrigerants. If you have any question, please feel free to contact us.