Home > Products > Refrigeration Solenoid Valve > Danfoss Type Solenoid Valve > EVR10 Series 1/2'' Solenoid Valve in Refrigeration

EVR10 Series 1/2'' Solenoid Valve in Refrigeration

Payment Type:
L/C,T/T,Paypal,Western Union
Incoterm:
FOB,CFR,EXW
Min. Order:
1 Set/Sets
Transportation:
Ocean,Land,Air
Port:
Qingdao,Xianggang,Shenzhen
Share:
Chat Now
  • Product Description
Overview
Product Attributes

Model No.EVR10-012S

BrandBrando

ActuatorElectric

Connection FormFlange

TypeDirect Acting

MaterialBrass

PressureOrdinary Pressure

Valve StructureDirect-Acting Piston Structure

Power SupplyDC Solenoid Valve

UsageTemperature Control

StandardGB

ApplicationIndustrial Usage

Supply Ability & Additional Information

PackagingPallets,Cartons,Inner Boxes

Productivity1120 sets/ 1 week

TransportationOcean,Land,Air

Place of OriginNINGBO CHINA

Supply Ability4560 sets/ 1 month

CertificateCE

PortQingdao,Xianggang,Shenzhen

Payment TypeL/C,T/T,Paypal,Western Union

IncotermFOB,CFR,EXW

Packaging & Delivery
Selling Units:
Set/Sets
Package Type:
Pallets,Cartons,Inner Boxes

EVR10 Series 1/2'' Solenoid Valve in Refrigeration



EVR10 Series 1/2'' Solenoid Valve in Refrigeration is a direct acting structure. When the coil is energized, a magnetic field is formed to generate magnetic force and pull up the iron core. The small valve orifice of the piston is opened to discharge the pressure on the upper part of the piston. Under the action of pressure difference, the piston is pushed up and the main valve orifice is opened to form a path. Cut off the power supply, the iron core loses its magnetic force and automatically resets under the action of the spring and falls down. Close the small valve mouth of the piston. Pressure is formed on the top of the piston, which prompts the piston to press down and cut off the pipe.


Technical Parameters of EVR10 solenoid valve for refrigeration:

Model
Connection
H1
H2
H4
L
L2
KV Factor (m³/h)
SAE inlet/outlet ODF inlet/outlet (Solder) Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm
EVR3-014 EVR3-014S 1/4 6 0.5 14 2.8 71 - - 4.0 102 0.3 7 0.27
EVR3-038 EVR3-038S 3/8 10 0.5 14 2.9 73 - - 4.6 117 0.4 10
EVR6-038 EVR6-038S 3/8 10 0.5 14 3.1 79 - - 4.4 111 0.4 10 0.8
EVR6-012 EVR6-012S 1/2 12.8 0.5 14 3.1 79 - - 5.0 127 0.4 10
EVR10-012 EVR10-012S 1/2 12.8 0.6 16 3.1 79 - - 5.0 127 0.4 10 1.9
EVR10-058 EVR10-058S 5/8 16 0.6 16 3.1 79 - - 6.3 160 0.5 12

EVR15-058S 5/8 16 0.7 19 3.4 86 - - 6.9 176 0.5 12 2.6

EVR15-078S 7/8 22 0.7 19 3.4 86 - - 6.9 176 0.7 17

EVR20-078S 7/8 22 0.8 20 3.5 90 - - 7.5 191 0.7 17 5

EVR20-118S 1 1/8 28.8 0.8 20 3.5 90 - - 8.4 214 0.8 22

EVR22-138S 1 3/8 35 0.8 20 3.5 90 - - 11.1 281 1 25 6

EVR25-118S 1 1/8 28.8 1.5 38 5.4 138 2.8 72 10.0 256 0.8 22 10

EVR25-138S 1 3/8 35 1.5 38 5.4 138 2.8 72 11.0 281 1 25

EVR32-138S 1 3/8 35 1.9 47 4.4 111 2.1 53 11.0 281 1 25 16

EVR32-158S 1 5/8 42 1.9 47 4.4 111 2.1 53 11.0 281 1.1 29

EVR40-158S 1 5/8 42 1.9 47 4.4 111 2.1 53 11.0 281 1.1 29 25

EVR40-218S 2 1/8 54 1.9 47 4.4 111 2.1 53 11.0 281 1.3 34


Other information of EVR10 solenoid valve in refrigeration:

Applicable Refrigerant HCFC or HFC or CFC or customized
Applicable Medium Temperature -40~105℃
Applicable Ambient -40~80℃
Standard Voltage of Solenoid Coil AC380V AC220V 50/60HZ
Allowable Voltage Fluctuation for Solenoid +10%~-15%
Connection of Solenoid Terminal box

Component structure of EVR10-012S Refrigeration Electromagnetic Valve:

Component structure of EVR10-012S Refrigeration Electromagnetic Valve


EVR10-012S Solenoid valve in refrigeration system ((Ice machines):

EVR10-012S Solenoid valve in refrigeration system ((Ice machines)


Working principle of industrial chiller with EVR10-012S:


The industry commonly known as refrigerators, refrigerators, chillers, chillers, chillers, etc., as in various industries widely used, so the name is also numerous. The basic principle is a multifunctional machine, through compression or heat absorption refrigeration cycle to remove liquid vapor. The steam compression refrigerating machine is composed of four parts: a steam compression refrigeration cycle compressor, an evaporator, a condenser and a partial metering device for realizing different refrigerants. Absorption refrigerator USES water as refrigerant and relies on water and lithium bromide solution to achieve strong refrigeration affinity.


The working principle of the refrigerating machine is steam compression refrigeration, that is, using the principle of heat absorption when liquid refrigerant evaporates and heat release when steam condenses. In refrigeration, evaporation is the process by which a liquid refrigerant boils into a gaseous state. When you go from a liquid to a gas, you have to absorb heat from the outside. So this is an endothermic process. The temperature at which the liquid refrigerant evaporates is called the evaporation temperature. Condensation is the process of turning steam into liquid by cooling it to a temperature equal to or below saturation.


Technical and economic comparison of water cooling and air cooling units:

Given the large number of air cooled condensers in refrigeration units, it is usually difficult to arrange. On the other hand, too small water cooling units are not suitable for use, so for medium size air cooling units, the same amount of cooling. Water - cooled refrigeration units are compared.


Now compare a certain type of water-cooled refrigerating unit with the same air-cooled refrigerating unit, main engine and evaporator:The annual running time of the compressor is from 1000 hours to 3000 hours, and the annual running time of the cooling tower and the pump is from 1400 hours to 4200 hours.


Welcome to your inquiry!

Product Categories : Refrigeration Solenoid Valve > Danfoss Type Solenoid Valve

Home > Products > Refrigeration Solenoid Valve > Danfoss Type Solenoid Valve > EVR10 Series 1/2'' Solenoid Valve in Refrigeration
Email to this supplier
  • *Subject:
  • *To:
    Mr. Brandon Bao
  • *Mobile:
  • *Email:
  • *Message:
    Your message must be between 20-8000 characters
Send Inquiry
*
*
*

Related Products List

Home

Product

Whatsapp

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send