  • Product Description
Overview
Product Attributes

Model No.EVRA 25

BrandBrando

Max. Working Pressure42 Bar

Function2-Way NC (Normally Closed)

Reference Number032F6225(Without Coil), 032F803432(With Coil)

Connection TypeSteel Flange Set

Port Size1'' Inch, DN25

ActionServo Piston Operated

Normal Voltage110VAC, 220VAC, 230VAC, 24VDC

Valve Body MaterialCast Iron

Ambient Temp-40 To 80 °C

RefrigerantsR134a R22 R401A R402A R404A R407A R407B R407C R407F R409A R410A R421A R502 R507 R717

Supply Ability & Additional Information

PackagingPlastic bag, Box, Carton, Pallet

Productivity6000 pcs per month

TransportationOcean,Land,Air

Place of OriginChina Ningbo

Supply Ability1500 pcs per week

CertificateCE

PortNingbo,Guangzhou,Shanghai

Payment TypeT/T,Paypal,Money Gram,Western Union

IncotermFOB,CFR,CIF,EXW

Packaging & Delivery
Selling Units:
Piece/Pieces
Package Type:
Plastic bag, Box, Carton, Pallet

032F6225 EVRA 25 Flange Solenoid Valve For Ammonia


Product features of 032F803432 EVRA 25 Flange Solenoid Valve For Ammonia:

EVRA is a direct or servo operated solenoid valve for liquid, suction and hot gas lines with ammonia or fluorinated refrigerants. EVRA valves are supplied complete or as separate components, i.e. valve body, coil and flanges can be ordered separately. EVRA 25, 32 and 40 are servo operated piston valves.The valves are closed with currentless coil.The servo piston with main valve plate closes against the valve seat by means of the differential pressure between inlet and outlet side of the valve, the force of the compression spring and possibly the piston weight.When current to the coil is switched on, the pilot orifice opens. This relieves the pressure on the piston spring side of the valve. The differential pressure will then open the valve. The minimum differential pressure needed for full opening of the valves is 0.2 bar.


Overall dimension of 032F803432 EVRA 25 Flange Solenoid Valve For Ammonia:

032F6225 EVRA 25 Flange Solenoid Valve For Ammonia


Technical data of Danfoss Type NC Refrigeration Solenoid Valve For Refrigerant Control:

Type Opening differential pressure with standard coil ( ∆p bar) Temperature of medium (°C) Max. working pressure (bar) kv-value (m³/h)
Min. Max. (= MOPD) liquid²)
10W AC 12W AC 20W DC
EVRA 3 0.00 21 25 14 -40 to 105 42 0.23
EVRA 10 0.05 21 25 18 -40 to 105 42 1.5
EVRAT10 0.00 14 21 16 -40 to 105 42 1.5
EVRA 15 0.05 21 25 18 -40 to 105 42 2.7
EVRAT15 0.00 14 21 16 -40 to 105 42 2.7
EVRA 20 AC 0.05 21 25 13 -40 to 105 42 4.5
EVRA 20 DC 0.05 19 21 16 -40 to 105 42 4.5
EVRAT20 0.00 14 21 13 -40 to 105 42 4.5
EVRA 25 0.20 21 25 14 -40 to 105 42 10.0
EVRA 32 0.20 21 25 14 -40 to 105 42 16.0
EVRA 40 0.20 21 25 14 -40 to 105 42 25.0

Spare parts of 032F803432 EVRA 25 Cast Iron Body Ammonia Solenoid Valve:

032F803432 EVRA 25 Cast Iron Body Ammonia Solenoid Valve


Packing of 032F6225 EVRA 25 Servo-Piston Solenoid Valve With Two Flanges:

032F6225 EVRA 25 Servo-Piston Solenoid Valve With Two Flanges


Specifications to the Component Supplier:
1. All pipes shall be cleaned inside with dry air to remove residues after production and capped on both ends.
2. Optionally primed on outer surface (batch number shall still be visible).
3. Main components should be cleaned and dried inside after pressure test and delivered sealed and slightly pressurized with inert gas.
4. Refrigerant should have a controlled water content following local recommendations or requirements and not higher than below.

Instructions to the Fitter:

1. Disassemble the valve top and clean, lubricate (e.g. with refrigerant oil), protect sealing parts and store in a clean/dry place.
2. Use only pipes that are still capped and clean.
3. Remove metal burrs after drilling and grinding, e.g. using air and/or a magnet.
4. Cap any open pipe ends and don’t leave any tool cloths, cigarettes, tools etc. inside the pipes.
5. Clean and lubricate valve housing sealing surfaces (e.g. with refrigerant oil) and protect openings against rain and dust, e.g. with plastic.


Focus on your demands, Offer you best solution:


√ Contact us if some points you have doubt

√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for

√ Contact us if you are doing designing


Welcome to your any question and inquiry!

Product Categories : Refrigeration Solenoid Valve > Ammonia Solenoid Valve

Home > Products > Refrigeration Solenoid Valve > Ammonia Solenoid Valve > 032F803432 EVRA 25 Flange Solenoid Valve For Ammonia
Email to this supplier
  • *Subject:
  • *To:
    Mr. Brandon Bao
  • *Mobile:
  • *Email:
  • *Message:
    Your message must be between 20-8000 characters
Send Inquiry
*
*
*

Related Products List

Home

Product

Whatsapp

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send