Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Model No.: BB16050020
Brand: Brando
Color: Black
Connection Type: DIN43650A
Insulation Class: H, F
Name: Hydraulic Solenoid Coil
Voltage: DC12V, DC24V (±10%)
Type: Amisco Type EVI 3P/16
Power: DC: 26W
Material: Plastic, Brass
Application: Hydraulic Cartridge Solenoid Check Valve
Main Dimension: 16mm X 37.5mm X 50mm
Packaging: Boxes, Carton, Pallet
Productivity: 450000 pcs per month
Transportation: Ocean,Land
Place of Origin: China Ningbo
Supply Ability: 110000 pcs per week
Certificate: CE
Port: Ningbo,Shanghai,Guangzhou
Payment Type: L/C,T/T,Paypal,Money Gram,Western Union
Incoterm: FOB,CFR,CIF,EXW,FCA
Amisco Type EVI 3P/16 Hydraulic Solenoid Valve Coil
This Amisco Type EVI 3P/16 coil is widely used in hydraulic check valves. Check valves are used in hydraulic systems to prevent reverse flow of oil flow or in pneumatic systems to prevent reverse flow of compressed air. The pilot operated check valve is also called a lock valve or a pressure maintaining valve. It is the same as the check valve to prevent reverse flow of oil. However, when the oil flow needs to flow in the opposite direction in the hydraulic circuit, the control oil pressure can be utilized to open the check valve so that the oil flow can flow in both directions. The pilot operated check valve uses a conical spool, so the sealing performance is good. When a closed oil circuit is required, this valve can be used as a one-way locking of the oil passage to maintain the pressure. The hydraulic control check valve controls the leakage of oil in the form of internal leakage and external leakage. The internal venting type can be used in the oil passage with no back pressure at the reverse flow of the oil flow; otherwise, the external venting type is required to reduce the control oil pressure.
Technical data of Amisco Type EVI 3P/16 Hydraulic Solenoid Valve Coils:
Model No. BB16050020 Ref No. EVI 3P/16 Normal voltage DC12V, DC24V (±10%) Normal power DC: 26W Material Plastic, Brass Wire class H, F Connection DIN43650A Application Hydraulic Cartridge Solenoid Check Valve Hole size 16 mm Height 37.5 mm Width 50 mm
Overall dimension of EVI 3P/16 DIN43650A AMISCO Hydraulic Coils:
Details enlargement of DC24V/AC220V EVI 3P/16 Solenoid Valve Coils:
Multi-angle display of 16mm x 37.5mm x 50mm EVI 3P/16 Check Valve Hydraulic Coil:
1. The role of the Solenoid Valve Coil
The movable iron core in the solenoid valve coil is attracted by the coil when the valve is energized, and drives the spool to move, thereby changing the conduction state of the valve; the so-called dry or wet only refers to the working environment of the coil, and the valve action is not large. the difference. However, we know that the inductance of an air-core coil is different from the inductance of the iron core in the coil. The former is small and the latter is large. When the coil is connected to alternating current, the impedance generated by the coil is not Similarly, for the same coil, when the same frequency of alternating current is applied, the inductance will change with the position of the core, that is, its impedance changes with the position of the core. When the impedance is small, the current flowing through the coil will increase.
2. The reason why the solenoid valve coil is often too warm
When the coil of the solenoid valve is in operation (energized), the core is attracted to form a closed magnetic circuit. That is, when the inductance is at the maximum state, the design time. The heat is normal, but the core can not be smoothly connected when the core is energized. The inductance of the coil is reduced, the impedance is reduced, and the current is increased accordingly. This causes the coil current to be too large and the life is affected. Therefore, the oil is blocked and the action is slow. It can't even be fully absorbed, so that when the coil is energized, it is often in a state where the impedance is less than normal, which may be the factor of the coil.
3. Solenoid valve coil quality detection
Use a multimeter to measure the resistance of the solenoid valve. The resistance of the coil should be around 100 ohms! If the resistance of the coil is infinite, it means that the solenoid valve can be energized and placed on the solenoid valve. Because the solenoid valve is energized, the solenoid valve has magnetic properties to attract the iron product. If you can hold the iron product, the coil is good, and the anti-knowledge indicates that the coil is broken!
4. Solenoid valve coil short circuit or open circuit
Detection method: first measure the on-off with a multimeter, the resistance value is close to zero or infinity, which means that the coil is short-circuited or open circuit. If the measured resistance is normal (probably tens of ohms), it can not be said that the coil must be good (I once measured a solenoid valve coil resistance of about 50 ohms, but the solenoid valve can not move, after replacing the coil, everything is normal ), please perform the following final test: find a small screwdriver placed near the metal rod in the coil of the solenoid valve, and then energize the solenoid valve. If it feels magnetic, the solenoid valve coil is good, otherwise it is bad. .
Treatment method: Replace the solenoid valve coil.
Welcome to your any question and inquiry!