Model No.: BB09325013
Brand: Brando
Insulation: H
Connection: DEUTCH
Name: 3 Ohms CNG Injector Rail Solenoid Coil
Replacement: OMB / Valtek / Tomasetto Type
Reference Number: 3ohm Injector Type 30 / 33 / 37 / 40, 3ohms IR3045 / IR3020 / IR3087
Voltage: DC12V (±10%, Other Can Be Customized)
Power: DC:48Watt
Material: Thermoplastic Composite Or Flame Retardant Resin
Dimension: φ9mm X 29.2mm X 25mm
Application: OMB / Valtek / Tomasetto Type CNG Injector Rail & On / Off Shut-off Solenoid Valve
Packaging: Plastic bag, Box, Carton, Pallet
Productivity: 300000 pcs per month
Transportation: Ocean,Land,Air
Place of Origin: Ningbo China
Supply Ability: 70000 pcs per week
Certificate: CE
Port: Ningbo,Guangzhou,Shanghai
Payment Type: L/C,T/T,Paypal,Money Gram,Western Union
Incoterm: FOB,CFR,CIF,EXW
OMB lg1 Injector Rail Solenoid Coil 3 Ohms
The 3 Ohms Solenoid Coil For OMB / Valtek / Tomasetto Injector Rail is made of thermoplastic composite material or flame retardant heat-resistant resin. Excellent resistance to high temperature and moisture. Widely used in car dual fuel CNG refit system, gas common rail, motorcycle device. Commonly used voltage resistance DC12V / 3 Ω / 6 Ω / 8 Ω.
Working principle of spraying rail:
1. The gas is stored in the guide rail and sprayed through the nozzle to the engine inlet pipe.
2. Computer controlled nozzle injection. 3 or 4 nozzles are installed on the guide rail to suit different models.
3. The temperature and pressure of the gas entering the guide rail can be monitored. The maximum operating pressure is 300Kpa.
4. When the electromagnetic coil of the spray rail is energized, the suction will be generated, the needle valve will be sucked up, and the nozzle hole will be opened. The gas will be ejected at a high speed through the annular gap between the shaft needle and the nozzle at the head of the needle valve, forming a fog, which is conducive to full combustion.
Technical data of 3 Ohms Solenoid Coil For OMB Injector Rail:
Model number BB09325013 Reference number 3ohm injector type 30 / 33 / 37 / 40, 3ohms IR3045 / IR3020 / IR3087
Normal voltage DC12V (±10%, other can be customized) Normal resistance 3 ohms Normal power DC:48Watt Material Plastic, Brass Wire class H Connection DEUTCH Application OMB / Valtek / Tomasetto Type CNG Injector Rail and On / Off shut-off Solenoid Valve Hole diameter 9 mm Height 29.2 mm Width 25 mm
Overall dimension of Valtek 3ohm Injector Type 30 / 33 / 37 / 40 Coils:
Detail enlargement of Tomasetto Rail Injecotrs Accessories Solenoid Coil:
Applied in CNG Injector Rail and On / Off shut-off Solenoid Valve:
Production display of Omb Cng lg1 rail injector Coil:
Question 1: Is there an electromagnetic coil for the automotive industry?
Answer: Yes, we do the Solenoid Valve Coils of the automotive industry, including car engines, car gearboxes, car exhaust, car suspension systems and automotive ABS anti-lock systems.
Question 2: How to choose a suitable Solenoid Valve Coil?
Answer: Users can provide us with a series of solenoid valve coil data, such as solenoid valve coil pressure, solenoid valve body material, interface size and media, etc. We will recommend suitable products for customers.
Note on the use of solenoid valve coil:
1. When the coil is energized, it is strictly forbidden to cover to prevent overheating and burning;
2. Electromagnetic coils, sockets, electromagnets and connecting parts are strictly prohibited from hitting the collision to avoid damage;
3. When the coil is energized for normal operation, due to its own heat, the temperature is high, please do not touch it;
4. The working pressure, temperature and viscosity of the medium shall not exceed the specified range;
5. The actual power supply voltage must not exceed the specified range;
6. Ordinary solenoid valve coils should not be used in explosive places;
7. The internal parts of the solenoid valve and the filtering device must be cleaned regularly;
8. Check the model and parameters on the valve label, which must meet the technical requirements of the site;
9. Check the coil, electromagnet and electrical socket to ensure no external damage;
10. When the solenoid valve coil is not used for a while, it can be stored in the room where 0 °C - 40 °C, relative humidity <80%, and no corrosive gas, no open storage is allowed;
11. When the electromagnetic valve is installed in the open air, a protective cover must be installed to ensure performance and extend the service life;
12. The AC solenoid valve coil must not be energized at no load, otherwise there is a danger of burning;
13. The best installation method of the solenoid valve is perpendicular to the horizontal pipe, the coil is upward, and the maximum inclination angle is <30° during installation. Otherwise, normal use cannot be guaranteed;
14. Clean and purify the pipeline. The working medium of the solenoid valve should be clean. If the medium contains particulate impurities, a filter device must be installed on the pipeline before the valve.
15. Connect the valve's interface to the pipe according to the direction indicated by the arrow on the valve body, and ensure that the joint is well sealed.
Welcome to your any question and inquiry!
Product Categories : Solenoid Valve Coil > Solenoid Valve Coils
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.