Overview
Product Attributes

Model No.BB14439333

BrandBRANDO

Insulation ClassH

ConnectionDIN43650A

NamePulse Diaphragm Valve Coils

Main MaterialCopper

TypeASCO Type Pulse Valve Accessories Coils

Inner Hole14mm

Height39.3mm

Standard VoltageAC220Volt / 24Volt DC

Standard PowerAC: 21VA DC:18W

Weight311.5 G

Supply Ability & Additional Information

PackagingPallet,Carton,Box

Productivity60000 sets per week

TransportationOcean,Land,Air

Place of OriginNINGBO CHINA

Supply Ability260000 sets per month

CertificateCE,GB,ISO

PortNingbo,Yiwu,Guangzhou

Payment TypeL/C,T/T,Paypal,Money Gram,Western Union

IncotermFOB,CFR,CIF,EXW

Packaging & Delivery
Selling Units:
Piece/Pieces
Package Type:
Pallet,Carton,Box

14mm Hole Diameter MP-C-146 8353 Series Electromagnetic Coil


The solenoid coil is mainly used in the Solenoid Valve, and the main purpose of the solenoid valve is to control the valve switch, or the liquid flow control, or the access control switch, etc., and the application is very extensive. The pulse diaphragm valve coil is described below.


The solenoid valve is a valve that attracts a ferromagnetic substance (moving iron core) by a strong magnetic field generated by a coil that is energized. The main control components consist of an electromagnetic coil, a static iron core, and a moving iron core. During operation, the current flows into the coil to generate a magnetic field, so that both the static iron core and the moving iron core are magnetized, and the moving iron core is attracted by the electromagnetic force and the static iron core is attracted. When the power is turned off, the magnetic field disappears, and the moving iron core is in the elastic force. Released under the influence of.


Technical parameter of ASCO type copper pulse diaphragm valve coils:

Model BB14439333
Standard voltage AC220V; DC24V; or customized
Standard power AC: 21VA DC:18W
Insulation class H
Connection type DIN43650A
Application ASCO type pulse valve accessories coils
Weight 311.5 g

Main dimension of 14mm inner hole height 39.3mm Pulse Jet Valve accessories coils:


Main dimension of 14mm inner hole height 39.3mm pulse jet valve accessories coils

Automatic winding machine of AC220Volt/24VoltageDC Refrigerant Control Coil:

Automatic winding machine of AC220Volt/24VoltageDC Refrigerant Control Coil


Wire lead type ASCO pulse diaphragm valve spare part coils:


Wire lead type ASCO pulse diaphragm valve spare part coilsWire lead type ASCO pulse diaphragm valve spare part coils


Pulse Valve Solenoid Coil burnout detection method:

The reason why the pulse valve does not work may be: the power supply is cut off or the cleaning controller is out of order, the pulse valve of the pulse dust collector has debris, the air leaks all the time, the pulse valve coil burns out, and the compressed air pressure is too low.
 
Remedy: Restore power or repair the cleaning controller, carefully clean the pulse valve, change the pulse valve coil, check the pneumatic system and compressor.

Use the multimeter to measure the resistance of the attracting coil and the holding coil separately. The resistance of the attracting coil is generally below ohms, while the resistance of the holding coil is generally around 1 ohm. If the multimeter pointer does not swing, that is, the resistance is infinite, indicating that the line is open; if the resistance is less than the specified value, the line is short-circuited. If the wire is broken or shorted, it needs to be replaced.


Right angle electromagnetic pulse valve power supply application conditions:

1. According to the type of power supply, AC and DC solenoid valves are used respectively. Generally speaking, AC power is convenient to use.

2. For voltage specifications, use AC220V and DC24V as much as possible.

3, the power supply voltage fluctuations are usually AC +% 10%, -15%, DC allows ±% 10 or so, if the difference is excessive, it is necessary to take pressure measures or put forward special order requirements.

4. The rated current and power consumption should be selected according to the power supply capacity. It should be noted that the VA value is higher when the AC starts, and the indirect guided solenoid valve should be preferred when the capacity is insufficient.

Right angle electromagnetic pulse valve installation and use:

1. Check to see if the components are damaged during transportation.

2. Before installation, ventilate the debris in the gas supply pipeline, and pay attention to the gas flow direction and the correct connection when installing.

3. All O-rings should be coated with a suitable lubricant during installation.

4. The air separator (including the connecting pipe) of the dust collector is customized by the user. The capacity of the gas distribution box should meet the gas source that provides stable operation of the electromagnetic pulse valve. The inner wall of the gas distribution box should be clean and free of rust and other debris, and the gas distribution box has no leakage. And in line with the requirements of stability.

5. The sealing temperature of the electromagnetic pulse valve and the air bag and the spray connection pipe is applicable to a temperature of -10 ° C to 70 ° C. If high temperature seals are required, please specify otherwise when ordering.

6. There are three pins on the electromagnetic pulse valve coil, and they are equipped with special plugs. One of them has a symbol for the grounding pin. The user can decide whether to ground or not according to the need. (In general, when the voltage is less than 36V, it can be grounded. When it is greater than 36V, it should be grounded.) The other two are coil power pins, which are connected to the terminals of the pulse blowing controller and the terminals of the valve common line. Pay attention to whether the voltage meets the requirements.


Pls contact us for more details!

Product Categories : Solenoid Valve Coil > Solenoid Valve Coils

Home > Products > Solenoid Valve Coil > Solenoid Valve Coils > 14mm Hole Diameter MP-C-146 8353 Series Electromagnetic Coil
Email to this supplier
  • *Subject:
  • *To:
    Mr. Brandon Bao
  • *Mobile:
  • *Email:
  • *Message:
    Your message must be between 20-8000 characters
Send Inquiry
*
*
*

Related Products List

Home

Product

Whatsapp

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send