Model No.: DMF-Y-40S
Brand: brando
Pressure: Ordinary Pressure
Application: General
Power: Solenoid
Body Material: Aluminum
Type: Solenoid Valve
Brand: Brando
Temperature: -25℃ To +80℃
Media: Air
Voltage: AC 220V 110V DC 24V 12V
Diaphragm Material: NBR FKM
Port Size: 1 1/2 Inch
Packaging: Box, Carton, Pallet
Productivity: 20000 sets per week
Transportation: Ocean,Land,Air
Place of Origin: zhejiang
Supply Ability: 150000 pieces per month
Certificate: CE
Port: Ningbo,Shanghai,Guangzhou
Payment Type: L/C,T/T,Paypal,Money Gram,Western Union
Incoterm: FOB,CFR,EXW
AC220V 110V DC 24V 12V 1 1/2'' Inch DN40 Double Diaphragms DMF-Y-40S Electromagnetic Pulse Control Valve
DMF-Y-40S 1.5″ pulse jet valves , DMF sbfec series pulse Solenoid Valve embedded type 1. Tank mounted diaphragm valve system with special springless piston/diaphragm design offers highest peak pressure and best flow performance operating features required for dust collector applications. 2. The high quality diaphragm guarantees a long operating life and a large temperature range. 3. Possible to apply different combinations of pitch distances and up to 24 valves.
DMF-Y-40S 1.5″ pulse jet valves , DMF sbfec series pulse solenoid valve embedded type
1. Tank mounted diaphragm valve system with special springless piston/diaphragm design offers highest peak pressure and best flow performance operating features required for dust collector applications.
2. The high quality diaphragm guarantees a long operating life and a large temperature range.
3. Possible to apply different combinations of pitch distances and up to 24 valves..
4. Each to connect to other tank systems. Service connections for different accessories such as: filter regulator, pressure gauge, safety and automatic/manual drain valve.
5. Several blow pipe connections available, such as: quick mount, push-in, hose or threaded connection.
Technical data chart of DMF Y series solenoid pulse valves in industrial filter use:
Model Numbers | DMF-Y-25 | DMF-Y-40S | DMF-Y-50S | DMF-Y-62S | DMF-Y-76S | DMF-Y-102S |
Port size | G1'' | G1 1/2'' | G2'' | G2 1/2'' | G3'' | G4'' |
Membrane sizes (φ66 smaller) | φ96 | φ112 | φ160 | φ188 | φ202 | φ255 |
CV values | 30.53 | 53.47 | 71.47 | 150.85 | 186.66 | 313.09 |
Blowing area (m2) | 8-10 | 12-16 | 18-28 | 27-38 | 37-65' | 70-90 |
Weighgt (kg) | 0.75 | 1.2 | 2.35 | 3.2 | 4.05 | 6.65 |
Environment Temperature | -25℃-80℃ or customized | |||||
Relative Humidity | ≤85% | |||||
Working Medium | Clean Air | |||||
Protection class | IP 65 | |||||
Service life cycle | Over million times | |||||
Voltages | AC110V/AC220V/DC12V/DC24V/12VDC |
Overall dimension of DMF-Y-40S Pneuamtic Pulse Solenoid Valve Aluminum Body for Dust Collector:
Detail Images Of DMF Series Control Solenoid Valve:
Tips: All accessories can be sold separately as repair parts (Diaphragm, Solenoid Coil, Armature Assembly)
Youtube video of DMF Dust Collector Pulse Solenoid Valve
Working place view of DMF clean air solenoid Pulse Jet Valve single diaphragm:
Common faults and repair methods of DMF membrane pulse solenoid valve:
1. The spring is damaged. The spring on the pulse valve spool is easily damaged. The appearance is that the pulse valve is deflated to the blow port for a long time. The treatment method is to replace the spring.
2. the valve core dirt, because the intake air is not clean, causing the fouling of the valve core, resulting in the appearance of long-term intake of the nozzle or the pulse valve does not work after the power, the treatment method is to clean the valve core.
3. the diaphragm is damaged, after long-term work, the diaphragm is easy to fatigue, oxidation, etc., resulting in the appearance of long-term deflation of the pressure relief port, the pulse valve does not work, the treatment is to replace the diaphragm.
4. The rubber pad is damaged. After the use time is long, the rubber pad on the pulse valve spool is easily damaged. The appearance is that the pulse valve is deflated to the blowing port for a long time. The treatment method is to replace the rubber pad.
5. The orifice is blocked or damaged. The intake air is not clean and the throttle hole is blocked. The appearance is that the pulse valve is deflated to the nozzle for a long time. The treatment method is to clean the orifice; the orifice is damaged or missing, and the orifice is made. Loss of interception, resulting in abnormal pressure relief, the appearance of the pulse valve after the power is activated, the pressure relief port deflation, but the pulse valve is not sprayed, the treatment is a replacement orifice.
Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing
Welcome to your any question and inquiry!
Product Categories : Dust Collector Pulse Valve > Pulse Jet Valve
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.